Review





Similar Products

94
Innoprot Inc human brain vascular pericytes hvpcs
Human Brain Vascular Pericytes Hvpcs, supplied by Innoprot Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/10__1113_slash_jp291064-90-24-30
Average 94 stars, based on 1 article reviews
human brain vascular pericytes hvpcs - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

94
iXCells Biotechnologies human brain vascular pericytes
Human Brain Vascular Pericytes, supplied by iXCells Biotechnologies, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/pm41194141-112-21-28
Average 94 stars, based on 1 article reviews
human brain vascular pericytes - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

94
Innoprot Inc innoprot p10363
Innoprot P10363, supplied by Innoprot Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/10__1002_slash_admt__202502614-284-4-4
Average 94 stars, based on 1 article reviews
innoprot p10363 - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

94
Innoprot Inc vascular pericytes
Vascular Pericytes, supplied by Innoprot Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/pmc12818715-142-17-19
Average 94 stars, based on 1 article reviews
vascular pericytes - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

94
Innoprot Inc human brain vascular pericytes
Human Brain Vascular Pericytes, supplied by Innoprot Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/pmc12818715-142-15-19
Average 94 stars, based on 1 article reviews
human brain vascular pericytes - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

94
Innoprot Inc brain vascular pericytes hbvps
Microfluidic BBB-on-chip design and validation. A. Schematic representation of the BBB-on-chip, seeded with endothelial cells on the blood side and <t>pericytes</t> and astrocytes on the brain side, equipped with three microwells for 3D GBM spheroid culture (GBM spheroids area). B. Image of the assembled BBB-on-chip showing the upper channel (yellow) mimicking the vascular compartment and main perfusion conduit, and the lower channels (red) leading to the tumor compartment (scale bar = 2 cm). C. Transendothelial electrical resistance (TEER) measurements recorded daily across the membrane between the upper and lower channels and supporting the BBB. D. Permeability coefficients calculated from the diffusion of 40, 70, and 150 kDa FITC-dextrans through the assembled BBB-on-chip in the following conditions: i. No cells (control, membrane without cells), ii. Blood side (membrane + HUVECs endothelial monolayer), and iii. BBB complete (membrane with the three-culture of HUVECs on the blood side and pericytes and astrocytes on the brain side). E . IF staining of the BBB-on-chip model on day 7. On the blood side compartment , endothelial tight junction protein ZO-1 (green) and the endothelial marker CD31 (green) are expressed, confirming the formation of a continuous endothelial layer. On the brain side , astrocytes are identified by GFAP expression (magenta), indicating appropriate localization. DAPI (blue) highlights cell nuclei in both compartments. Scale bar = 50 μm. Values are expressed as median±SEM from at least 3 independent experiments. ∗p < 0.05, ∗∗p < 0.01 and ∗∗∗p < 0.001 vs control. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Brain Vascular Pericytes Hbvps, supplied by Innoprot Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/pmc12615336-235-37-48
Average 94 stars, based on 1 article reviews
brain vascular pericytes hbvps - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

94
Innoprot Inc human brain pericytes
Microfluidic BBB-on-chip design and validation. A. Schematic representation of the BBB-on-chip, seeded with endothelial cells on the blood side and <t>pericytes</t> and astrocytes on the brain side, equipped with three microwells for 3D GBM spheroid culture (GBM spheroids area). B. Image of the assembled BBB-on-chip showing the upper channel (yellow) mimicking the vascular compartment and main perfusion conduit, and the lower channels (red) leading to the tumor compartment (scale bar = 2 cm). C. Transendothelial electrical resistance (TEER) measurements recorded daily across the membrane between the upper and lower channels and supporting the BBB. D. Permeability coefficients calculated from the diffusion of 40, 70, and 150 kDa FITC-dextrans through the assembled BBB-on-chip in the following conditions: i. No cells (control, membrane without cells), ii. Blood side (membrane + HUVECs endothelial monolayer), and iii. BBB complete (membrane with the three-culture of HUVECs on the blood side and pericytes and astrocytes on the brain side). E . IF staining of the BBB-on-chip model on day 7. On the blood side compartment , endothelial tight junction protein ZO-1 (green) and the endothelial marker CD31 (green) are expressed, confirming the formation of a continuous endothelial layer. On the brain side , astrocytes are identified by GFAP expression (magenta), indicating appropriate localization. DAPI (blue) highlights cell nuclei in both compartments. Scale bar = 50 μm. Values are expressed as median±SEM from at least 3 independent experiments. ∗p < 0.05, ∗∗p < 0.01 and ∗∗∗p < 0.001 vs control. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Human Brain Pericytes, supplied by Innoprot Inc, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/Human+Brain+Vascular+Pericytes/bio_rxiv__2025__10__25__684548-65-0-4
Average 94 stars, based on 1 article reviews
human brain pericytes - by Bioz Stars, 2026-08
94/100 stars
  Buy from Supplier

86
Sanbio Inc human brain vascular pericytes
Microfluidic BBB-on-chip design and validation. A. Schematic representation of the BBB-on-chip, seeded with endothelial cells on the blood side and <t>pericytes</t> and astrocytes on the brain side, equipped with three microwells for 3D GBM spheroid culture (GBM spheroids area). B. Image of the assembled BBB-on-chip showing the upper channel (yellow) mimicking the vascular compartment and main perfusion conduit, and the lower channels (red) leading to the tumor compartment (scale bar = 2 cm). C. Transendothelial electrical resistance (TEER) measurements recorded daily across the membrane between the upper and lower channels and supporting the BBB. D. Permeability coefficients calculated from the diffusion of 40, 70, and 150 kDa FITC-dextrans through the assembled BBB-on-chip in the following conditions: i. No cells (control, membrane without cells), ii. Blood side (membrane + HUVECs endothelial monolayer), and iii. BBB complete (membrane with the three-culture of HUVECs on the blood side and pericytes and astrocytes on the brain side). E . IF staining of the BBB-on-chip model on day 7. On the blood side compartment , endothelial tight junction protein ZO-1 (green) and the endothelial marker CD31 (green) are expressed, confirming the formation of a continuous endothelial layer. On the brain side , astrocytes are identified by GFAP expression (magenta), indicating appropriate localization. DAPI (blue) highlights cell nuclei in both compartments. Scale bar = 50 μm. Values are expressed as median±SEM from at least 3 independent experiments. ∗p < 0.05, ∗∗p < 0.01 and ∗∗∗p < 0.001 vs control. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Human Brain Vascular Pericytes, supplied by Sanbio Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/human+brain+vascular+pericytes/brain+human+pericytes+vascular/bio_rxiv__2025__08__22__671484-235-7-11
Average 86 stars, based on 1 article reviews
human brain vascular pericytes - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

Image Search Results


Microfluidic BBB-on-chip design and validation. A. Schematic representation of the BBB-on-chip, seeded with endothelial cells on the blood side and pericytes and astrocytes on the brain side, equipped with three microwells for 3D GBM spheroid culture (GBM spheroids area). B. Image of the assembled BBB-on-chip showing the upper channel (yellow) mimicking the vascular compartment and main perfusion conduit, and the lower channels (red) leading to the tumor compartment (scale bar = 2 cm). C. Transendothelial electrical resistance (TEER) measurements recorded daily across the membrane between the upper and lower channels and supporting the BBB. D. Permeability coefficients calculated from the diffusion of 40, 70, and 150 kDa FITC-dextrans through the assembled BBB-on-chip in the following conditions: i. No cells (control, membrane without cells), ii. Blood side (membrane + HUVECs endothelial monolayer), and iii. BBB complete (membrane with the three-culture of HUVECs on the blood side and pericytes and astrocytes on the brain side). E . IF staining of the BBB-on-chip model on day 7. On the blood side compartment , endothelial tight junction protein ZO-1 (green) and the endothelial marker CD31 (green) are expressed, confirming the formation of a continuous endothelial layer. On the brain side , astrocytes are identified by GFAP expression (magenta), indicating appropriate localization. DAPI (blue) highlights cell nuclei in both compartments. Scale bar = 50 μm. Values are expressed as median±SEM from at least 3 independent experiments. ∗p < 0.05, ∗∗p < 0.01 and ∗∗∗p < 0.001 vs control. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)

Journal: Materials Today Bio

Article Title: Redirecting the route: Monocyte-mediated delivery of oHSV-1 across a human BBB-on-chip model

doi: 10.1016/j.mtbio.2025.102458

Figure Lengend Snippet: Microfluidic BBB-on-chip design and validation. A. Schematic representation of the BBB-on-chip, seeded with endothelial cells on the blood side and pericytes and astrocytes on the brain side, equipped with three microwells for 3D GBM spheroid culture (GBM spheroids area). B. Image of the assembled BBB-on-chip showing the upper channel (yellow) mimicking the vascular compartment and main perfusion conduit, and the lower channels (red) leading to the tumor compartment (scale bar = 2 cm). C. Transendothelial electrical resistance (TEER) measurements recorded daily across the membrane between the upper and lower channels and supporting the BBB. D. Permeability coefficients calculated from the diffusion of 40, 70, and 150 kDa FITC-dextrans through the assembled BBB-on-chip in the following conditions: i. No cells (control, membrane without cells), ii. Blood side (membrane + HUVECs endothelial monolayer), and iii. BBB complete (membrane with the three-culture of HUVECs on the blood side and pericytes and astrocytes on the brain side). E . IF staining of the BBB-on-chip model on day 7. On the blood side compartment , endothelial tight junction protein ZO-1 (green) and the endothelial marker CD31 (green) are expressed, confirming the formation of a continuous endothelial layer. On the brain side , astrocytes are identified by GFAP expression (magenta), indicating appropriate localization. DAPI (blue) highlights cell nuclei in both compartments. Scale bar = 50 μm. Values are expressed as median±SEM from at least 3 independent experiments. ∗p < 0.05, ∗∗p < 0.01 and ∗∗∗p < 0.001 vs control. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)

Article Snippet: The assembled BBB-on-chip devices were bound to glass coverslips via further plasma treatment and sterilized with 70 % ethanol followed by UV exposure for 60 min. BBB-on-chip cells seeding and culturing: Human umbilical vein endothelial cells (HUVECs), brain vascular pericytes (hBVPs), and immortalized astrocytes (hAs) were obtained from Innoprot (Derio, Spain).

Techniques: Biomarker Discovery, Membrane, Permeability, Diffusion-based Assay, Control, Staining, Marker, Expressing